Online User Manuals Go to the Cover and Bookmark Page Open the PDF version DP-OPT-150 Series User Manual

3.5. Powering On

ATTENTION!When building an electronic system, make sure that all of the devices are powered down before connecting them. Powered on devices may have dangerous voltage levels, which can damage sensitive electronic circuits.

After the system is complete, connect the DC power cable to the extender unit and then to the power outlet. The unit is immediately powered ON.

After the extender units are initialized, the attached DP source and monitor can be powered on.

ATTENTION!If the power LED does not light up upon power-up, the unit is most likely damaged and further use is not advised. Please contact support@lightware.com.

INFO:The laser becomes enabled any time the transmitter is powered on. This is done to avoid accidental laser loss problems.

3.5.1. Setting up USB Devices

DP-OPT-RX150 handles USB HID devices (Human Interface Device), which are input devices like the mouse, keyboard, presenter, pointing device, etc. Even though USB HUBs are supported (like those keyboards, monitors that have built-in USB HUB), only two devices are available for extension at the same time.

When the transmitter is connected to the computer by the USB cable, it can be used as a local USB 2.0 HUB. To build the USB connection, do the following steps:

Step 1.Connect the supplied USB cable to the transmitter’s mini USB connector.

Step 2.Connect the other end of the USB cable into an empty USB slot on the computer.

Step 3.Connect the HID device(s) to the receiver.

INFO:If the previously used USB devices are connected through the extenders to the computer, they may be handled as new hardware by the operating system the first time.